Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 535
Filtrar
1.
Med Phys ; 51(4): 2413-2423, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38431967

RESUMO

BACKGROUND: Individuals with asthma can vary widely in clinical presentation, severity, and pathobiology. Hyperpolarized xenon-129 (Xe129) MRI is a novel imaging method to provide 3-D mapping of both ventilation and gas exchange in the human lung. PURPOSE: To evaluate the functional changes in adults with asthma as compared to healthy controls using Xe129 MRI. METHODS: All subjects (20 controls and 20 asthmatics) underwent lung function measurements and Xe129 MRI on the same day. Outcome measures included the pulmonary ventilation defect and transfer of inspired Xe129 into two soluble compartments: tissue and blood. Ten asthmatics underwent Xe129 MRI before and after bronchodilator to test whether gas transfer measures change with bronchodilator effects. RESULTS: Initial analysis of the results revealed striking differences in gas transfer measures based on age, hence we compared outcomes in younger (n = 24, ≤ 35 years) versus older (n = 16, > 45 years) asthmatics and controls. The younger asthmatics exhibited significantly lower Xe129 gas uptake by lung tissue (Asthmatic: 0.98% ± 0.24%, Control: 1.17% ± 0.12%, P = 0.035), and higher Xe129 gas transfer from tissue to the blood (Asthmatic: 0.40 ± 0.10, Control: 0.31% ± 0.03%, P = 0.035) than the younger controls. No significant difference in Xe129 gas transfer was observed in the older group between asthmatics and controls (P > 0.05). No significant change in Xe129 transfer was observed before and after bronchodilator treatment. CONCLUSIONS: By using Xe129 MRI, we discovered heterogeneous alterations of gas transfer that have associations with age. This finding suggests a heretofore unrecognized physiological derangement in the gas/tissue/blood interface in young adults with asthma that deserves further study.


Assuntos
Asma , Broncodilatadores , Adulto Jovem , Humanos , Adulto , Broncodilatadores/uso terapêutico , Barreira Alveolocapilar , Pulmão/diagnóstico por imagem , Asma/diagnóstico por imagem , Asma/tratamento farmacológico , Isótopos de Xenônio , Imageamento por Ressonância Magnética/métodos , Xenônio/uso terapêutico
2.
Int J Mol Sci ; 25(3)2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38339217

RESUMO

Molecular magnetic resonance imaging (MRI) is an emerging field that is set to revolutionize our perspective of disease diagnosis, treatment efficacy monitoring, and precision medicine in full concordance with personalized medicine. A wide range of hyperpolarized (HP) 129Xe biosensors have been recently developed, demonstrating their potential applications in molecular settings, and achieving notable success within in vitro studies. The favorable nuclear magnetic resonance properties of 129Xe, coupled with its non-toxic nature, high solubility in biological tissues, and capacity to dissolve in blood and diffuse across membranes, highlight its superior role for applications in molecular MRI settings. The incorporation of reporters that combine signal enhancement from both hyperpolarized 129Xe and chemical exchange saturation transfer holds the potential to address the primary limitation of low sensitivity observed in conventional MRI. This review provides a summary of the various applications of HP 129Xe biosensors developed over the last decade, specifically highlighting their use in MRI. Moreover, this paper addresses the evolution of in vivo applications of HP 129Xe, discussing its potential transition into clinical settings.


Assuntos
Imageamento por Ressonância Magnética , Isótopos de Xenônio , Isótopos de Xenônio/química , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Solubilidade , Xenônio/química
3.
J Thorac Imaging ; 39(2): 79-85, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37889567

RESUMO

PURPOSE: This study aimed to determine the association between functional impairment in small airways and symptoms of dyspnea in patients with Long-coronavirus disease (COVID), using imaging and computational modeling analysis. PATIENTS AND METHODS: Thirty-four patients with Long-COVID underwent thoracic computed tomography and hyperpolarized Xenon-129 magnetic resonance imaging (HP Xe MRI) scans. Twenty-two answered dyspnea-12 questionnaires. We used a computed tomography-based full-scale airway network (FAN) flow model to simulate pulmonary ventilation. The ventilation distribution projected on a coronal plane and the percentage lobar ventilation modeled in the FAN model were compared with the HP Xe MRI data. To assess the ventilation heterogeneity in small airways, we calculated the fractal dimensions of the impaired ventilation regions in the HP Xe MRI and FAN models. RESULTS: The ventilation distribution projected on a coronal plane showed an excellent resemblance between HP Xe MRI scans and FAN models (structure similarity index: 0.87 ± 0.04). In both the image and the model, the existence of large clustered ventilation defects was not identifiable regardless of dyspnea severity. The percentage lobar ventilation of the HP Xe MRI and FAN model showed a strong correlation (ρ = 0.63, P < 0.001). The difference in the fractal dimension of impaired ventilation zones between the low and high dyspnea-12 score groups was significant (HP Xe MRI: 1.97 [1.89 to 2.04] and 2.08 [2.06 to 2.14], P = 0.005; FAN: 2.60 [2.59 to 2.64] and 2.64 [2.63 to 2.65], P = 0.056). CONCLUSIONS: This study has identified a potential association of small airway functional impairment with breathlessness in Long-COVID, using fractal analysis of HP Xe MRI scans and FAN models.


Assuntos
Síndrome Pós-COVID-19 Aguda , Isótopos de Xenônio , Humanos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Respiração , Imageamento por Ressonância Magnética/métodos , Dispneia/diagnóstico por imagem
4.
Magn Reson Med ; 91(4): 1541-1555, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38084439

RESUMO

PURPOSE: The interaction between 129 Xe atoms and pulmonary capillary red blood cells provides cardiogenic signal oscillations that display sensitivity to precapillary and postcapillary pulmonary hypertension. Recently, such oscillations have been spatially mapped, but little is known about optimal reconstruction or sensitivity to artifacts. In this study, we use digital phantom simulations to specifically optimize keyhole reconstruction for oscillation imaging. We then use this optimized method to re-establish healthy reference values and quantitatively evaluate microvascular flow changes in patients with chronic thromboembolic pulmonary hypertension (CTEPH) before and after pulmonary thromboendarterectomy (PTE). METHODS: A six-zone digital lung phantom was designed to investigate the effects of radial views, key radius, and SNR. One-point Dixon 129 Xe gas exchange MRI images were acquired in a healthy cohort (n = 17) to generate a reference distribution and thresholds for mapping red blood cell oscillations. These thresholds were applied to 10 CTEPH participants, with 6 rescanned following PTE. RESULTS: For undersampled acquisitions, a key radius of 0.14 k max $$ 0.14{k}_{\mathrm{max}} $$ was found to optimally resolve oscillation defects while minimizing excessive heterogeneity. CTEPH participants at baseline showed higher oscillation defect + low (32 ± 14%) compared with healthy volunteers (18 ± 12%, p < 0.001). For those scanned both before and after PTE, oscillation defect + low decreased from 37 ± 13% to 23 ± 14% (p = 0.03). CONCLUSIONS: Digital phantom simulations have informed an optimized keyhole reconstruction technique for gas exchange images acquired with standard 1-point Dixon parameters. Our proposed methodology enables more robust quantitative mapping of cardiogenic oscillations, potentially facilitating effective regional quantification of microvascular flow impairment in patients with pulmonary vascular diseases such as CTEPH.


Assuntos
Hipertensão Pulmonar , Pneumopatias , Humanos , Imageamento por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem , Eritrócitos , Isótopos de Xenônio
5.
J Vis Exp ; (201)2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-38078603

RESUMO

Hyperpolarized 129Xe MRI comprises a unique array of structural and functional lung imaging techniques. Technique standardization across sites is increasingly important given the recent FDA approval of 129Xe as an MR contrast agent and as interest in 129Xe MRI increases among research and clinical institutions. Members of the 129Xe MRI Clinical Trials Consortium (Xe MRI CTC) have agreed upon best practices for each of the key aspects of the 129Xe MRI workflow, and these recommendations are summarized in a recent publication. This work provides practical information to develop an end-to-end workflow for collecting 129Xe MR images of lung ventilation according to the Xe MRI CTC recommendations. Preparation and administration of 129Xe for MR studies will be discussed and demonstrated, with specific topics including choice of appropriate gas volumes for entire studies and for individual MR scans, preparation and delivery of individual 129Xe doses, and best practices for monitoring subject safety and 129Xe tolerability during studies. Key MR technical considerations will also be covered, including pulse sequence types and optimized parameters, calibration of 129Xe flip angle and center frequency, and 129Xe MRI ventilation image analysis.


Assuntos
Pulmão , Isótopos de Xenônio , Pulmão/diagnóstico por imagem , Pulmão/patologia , Imageamento por Ressonância Magnética/métodos , Xenônio
6.
ACS Sens ; 8(12): 4707-4715, 2023 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-38064687

RESUMO

Hyperpolarized (HP) xenon-129 (129Xe) magnetic resonance imaging (MRI) has the potential to be used as a molecular imaging modality. For this purpose, numerous supramolecular cages have been developed and evaluated in the past. Herein, we report a novel and unique macrocycle that can be successfully utilized for xenon MRI, the resorcinarene trimer methanesulfonate (R3-Noria-MeSO3H). This molecule is capable of two different contrast mechanisms for xenon-MRI, resulting from an increase in the effective spin-spin relaxation and hyperpolarized chemical exchange saturation transfer (HyperCEST). We have demonstrated a superior negative contrast caused by R3-Noria-MeSO3H on HP 129Xe MRI at 3.0 T as well as HyperCEST imaging of the studied macrocycle. Additionally, we have found that the complex aggregation behaviors of R3-Noria-methanesulfonate and its impact on xenon-129 relaxivity are an area for future study.


Assuntos
Imageamento por Ressonância Magnética , Isótopos de Xenônio , Imageamento por Ressonância Magnética/métodos , Isótopos de Xenônio/química , Xenônio/química , Meios de Contraste/química , Mesilatos
7.
J Vis Exp ; (201)2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-38009715

RESUMO

Hyperpolarized Xenon-129 (HXe) magnetic resonance imaging (MRI) provides tools for obtaining 2- or 3-dimensional maps of lung ventilation patterns, gas diffusion, Xenon uptake by lung parenchyma, and other lung function metrics. However, by trading spatial for temporal resolution, it also enables tracing of pulmonary Xenon gas exchange on a ms timescale. This article describes one such technique, chemical shift saturation recovery (CSSR) MR spectroscopy. It illustrates how it can be used to assess capillary blood volume, septal wall thickness, and the surface-to-volume ratio in the alveoli. The flip angle of the applied radiofrequency pulses (RF) was carefully calibrated. Single-dose breath-hold and multi-dose free-breathing protocols were employed for administering the gas to the subject. Once the inhaled Xenon gas reached the alveoli, a series of 90° RF pulses was applied to ensure maximum saturation of the accumulated Xenon magnetization in the lung parenchyma. Following a variable delay time, spectra were acquired to quantify the regrowth of the Xenon signal due to gas exchange between the alveolar gas volume and the tissue compartments of the lung. These spectra were then analyzed by fitting complex pseudo-Voigt functions to the three dominant peaks. Finally, the delay time-dependent peak amplitudes were fitted to a one-dimensional analytical gas-exchange model to extract physiological parameters.


Assuntos
Isótopos de Xenônio , Xenônio , Isótopos de Xenônio/química , Pulmão/diagnóstico por imagem , Pulmão/fisiologia , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética
8.
Chemphyschem ; 24(23): e202300346, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37713677

RESUMO

Molecular imaging is the future of personalized medicine; however, it requires effective contrast agents. Hyperpolarized chemical exchange saturation transfer (HyperCEST) can boost the signal of Hyperpolarized 129 Xe MRI and render it a molecular imaging modality of high efficiency. Cucurbit[6]uril (CB6) has been successfully employed in vivo as a contrast agent for HyperCEST MRI, however its performance in a clinical MRI scanner has yet to be optimized. In this study, MRI pulse sequence parameter optimization was first performed in CB6 solutions in phosphate-buffered saline (PBS), and subsequently in whole sterile citrated bovine blood. The performance of four different depolarization pulse shapes (sinusoidal, 3-lobe sinc (3LS), rectangular (block), and hyperbolic secant (hypsec) was optimized. The detectability limits of CB6 in a clinical 3.0T MRI scanner was assessed using the optimized pulse sequences. The 3LS depolarization pulses performed best, and demonstrated 24 % depletion in a 25 µM solution of CB6 in PBS. It performed similarly in blood. The CB6 detectability limit was found to be 100 µM in citrated bovine blood with a correspondent HyperCEST depletion of 30 % ±9 %. For the first time, the HP 129 Xe HyperCEST effect was observed in red blood cells (RBC) and had a similar strength as HyperCEST in plasma.


Assuntos
Imageamento por Ressonância Magnética , Isótopos de Xenônio , Animais , Bovinos , Espectroscopia de Ressonância Magnética/métodos , Isótopos de Xenônio/química , Imageamento por Ressonância Magnética/métodos , Meios de Contraste , Imagem Molecular
9.
Magn Reson Med ; 90(6): 2334-2347, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37533368

RESUMO

PURPOSE: To demonstrate the feasibility of a multi-breath xenon-polarization transfer contrast (XTC) MR imaging approach for simultaneously evaluating regional ventilation and gas exchange parameters. METHODS: Imaging was performed in five healthy volunteers and six chronic obstructive pulmonary disease (COPD) patients. The multi-breath XTC protocol consisted of three repeated schemes of six wash-in breaths of a xenon mixture and four normoxic wash-out breaths, with and without selective saturation of either the tissue membrane or red blood cell (RBC) resonances. Acquisitions were performed at end-exhalation while subjects maintained tidal breathing throughout the session. The no-saturation, membrane-saturation, and RBC-saturation images were fit to a per-breath gas replacement model for extracting voxelwise tidal volume (TV), functional residual capacity (FRC), and fractional ventilation (FV), as well as tissue- and RBC-gas exchange (fMem and fRBC , respectively). The sensitivity of the derived model was also evaluated via simulations. RESULTS: With the exception of FRC, whole-lung averages for all metrics were decreased in the COPD subjects compared to the healthy cohort, significantly so for FV, fRBC , and fMem . Heterogeneity was higher overall in the COPD subjects, particularly for fRBC , fMem , and fRBC:Mem . The anterior-to-posterior gradient associated with the gravity-dependence of lung function in supine imaging was also evident for FV, fRBC , and fMem values in the healthy subjects, but noticeably absent in the COPD cohort. CONCLUSION: Multi-breath XTC imaging generated high-resolution, co-registered maps of ventilation and gas exchange parameters acquired during tidal breathing and with low per-breath xenon doses. Clear differences between healthy and COPD subjects were apparent and consistent with spirometry.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Xenônio , Humanos , Pulmão/diagnóstico por imagem , Isótopos de Xenônio , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
10.
Magn Reson Med ; 90(6): 2420-2431, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37526031

RESUMO

PURPOSE: The underlying functional and microstructural lung disease in neonates who are born preterm (bronchopulmonary dysplasia, BPD) remains poorly characterized. Moreover, there is a lack of suitable techniques to reliably assess lung function in this population. Here, we report our preliminary experience with hyperpolarized 129 Xe MRI in neonates with BPD. METHODS: Neonatal intensive care patients with established BPD were recruited (N = 9) and imaged at a corrected gestational age of median:40.7 (range:37.1, 44.4) wk using a 1.5T neonatal scanner. 2D 129 Xe ventilation and diffusion-weighted images and dissolved phase spectroscopy were acquired, alongside 1 H 3D radial UTE. 129 Xe images were acquired during a series of short apneic breath-holds (˜3 s). 1 H UTE images were acquired during tidal breathing. Ventilation defects were manually identified and qualitatively compared to lung structures on UTE. ADCs were calculated on a voxel-wise basis. The signal ratio of the 129 Xe red blood cell (RBC) and tissue membrane (M) resonances from spectroscopy was determined. RESULTS: Spiral-based 129 Xe ventilation imaging showed good image quality and sufficient sensitivity to detect mild ventilation abnormalities in patients with BPD. 129 Xe ADC values were elevated above that expected given healthy data in older children and adults (median:0.046 [range:0.041, 0.064] cm2 s-1 ); the highest value obtained from an extremely pre-term patient. 129 Xe spectroscopy revealed a low RBC/M ratio (0.14 [0.06, 0.21]). CONCLUSION: We have demonstrated initial feasibility of 129 Xe lung MRI in neonates. With further data, the technique may help guide management of infant lung diseases in the neonatal period and beyond.


Assuntos
Displasia Broncopulmonar , Adulto , Recém-Nascido , Criança , Humanos , Displasia Broncopulmonar/diagnóstico por imagem , Estudos de Viabilidade , Isótopos de Xenônio , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
11.
Int J Mol Sci ; 24(14)2023 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-37511071

RESUMO

Hyperpolarized (HP) xenon-129 (129Xe), when dissolved in blood, has two NMR resonances: one in red blood cells (RBC) and one in plasma. The impact of numerous blood components on these resonances, however, has not yet been investigated. This study evaluates the effects of elevated glucose levels on the chemical shift (CS) and T2* relaxation times of HP 129Xe dissolved in sterile citrated sheep blood for the first time. HP 129Xe was mixed with sheep blood samples premixed with a stock glucose solution using a liquid-gas exchange module. Magnetic resonance spectroscopy was performed on a 3T clinical MRI scanner using a custom-built quadrature dual-tuned 129Xe/1H coil. We observed an additional resonance for the RBCs (129Xe-RBC1) for the increased glucose levels. The CS of 129Xe-RBC1 and 129Xe-plasma peaks did not change with glucose levels, while the CS of 129Xe-RBC2 (original RBC resonance) increased linearly at a rate of 0.015 ± 0.002 ppm/mM with glucose level. 129Xe-RBC1 T2* values increased nonlinearly from 1.58 ± 0.24 ms to 2.67 ± 0.40 ms. As a result of the increased glucose levels in blood samples, the novel additional HP 129Xe dissolved phase resonance was observed in blood and attributed to the 129Xe bound to glycated hemoglobin (HbA1c).


Assuntos
Reação de Maillard , Isótopos de Xenônio , Animais , Ovinos , Isótopos de Xenônio/química , Imageamento por Ressonância Magnética/métodos , Hemoglobinas , Glucose , Xenônio , Pulmão
12.
J Magn Reson ; 352: 107430, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37141801

RESUMO

The accuracy of inertial measurement performed by the nuclear magnetic resonance gyroscope (NMRG) with two isotopes depends on the duration of transverse relaxation. Extending the relaxation of the xenon isotopes at the same time plays a very important role in the accuracy of gyro. The relaxation time of 129Xe and 131Xe can be increased to about 15-20 s by optimizing the buffer gas pressure of N2 at about 0.57 amg and coating RbH, respectively. According to the results of theoretical analysis and experimentation, the gyro stability reaches 0.6°/h, and the active measurement volume is 3 × 3 × 3 âˆ¼ mm3.


Assuntos
Imageamento por Ressonância Magnética , Isótopos de Xenônio , Espectroscopia de Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Isótopos de Xenônio/química , Isótopos , Xenônio/química
13.
Magn Reson Med ; 90(4): 1555-1568, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37246900

RESUMO

PURPOSE: 129 Xe MRI and MRS signals from airspaces, membrane tissues (M), and red blood cells (RBCs) provide measurements of pulmonary gas exchange. However, 129 Xe MRI/MRS studies have yet to account for hemoglobin concentration (Hb), which is expected to affect the uptake of 129 Xe in the membrane and RBC compartments. We propose a framework to adjust the membrane and RBC signals for Hb and use this to assess sex-specific differences in RBC/M and establish a Hb-adjusted healthy reference range for the RBC/M ratio. METHODS: We combined the 1D model of xenon gas exchange (MOXE) with the principle of TR-flip angle equivalence to establish scaling factors that normalize the dissolved-phase signals with respect to a standard H b 0 $$ H{b}^0 $$ (14 g/dL). 129 Xe MRI/MRS data from a healthy, young cohort (n = 18, age = 25.0 ± $$ \pm $$ 3.4 years) were used to validate this model and assess the impact of Hb adjustment on M/gas and RBC/gas images and RBC/M. RESULTS: Adjusting for Hb caused RBC/M to change by up to 20% in healthy individuals with normal Hb and had marked impacts on M/gas and RBC/gas distributions in 3D gas-exchange maps. RBC/M was higher in males than females both before and after Hb adjustment (p < 0.001). After Hb adjustment, the healthy reference value for RBC/M for a consortium-recommended acquisition of TR = 15 ms and flip = 20° was 0.589 ± $$ \pm $$ 0.083 (mean ± $$ \pm $$ SD). CONCLUSION: MOXE provides a useful framework for evaluating the Hb dependence of the membrane and RBC signals. This work indicates that adjusting for Hb is essential for accurately assessing 129 Xe gas-exchange MRI/MRS metrics.


Assuntos
Imageamento por Ressonância Magnética , Isótopos de Xenônio , Masculino , Feminino , Humanos , Adulto , Imageamento por Ressonância Magnética/métodos , Hemoglobinas , Xenônio , Eritrócitos , Troca Gasosa Pulmonar , Gases , Pulmão
15.
NMR Biomed ; 36(8): e4923, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36914278

RESUMO

Hyperpolarized 129 Xe MRI (Xe-MRI) is increasingly used to image the structure and function of the lungs. Because 129 Xe imaging can provide multiple contrasts (ventilation, alveolar airspace size, and gas exchange), imaging often occurs over several breath-holds, which increases the time, expense, and patient burden of scans. We propose an imaging sequence that can be used to acquire Xe-MRI gas exchange and high-quality ventilation images within a single, approximately 10 s, breath-hold. This method uses a radial one-point Dixon approach to sample dissolved 129 Xe signal, which is interleaved with a 3D spiral ("FLORET") encoding pattern for gaseous 129 Xe. Thus, ventilation images are obtained at higher nominal spatial resolution (4.2 × 4.2 × 4.2 mm3 ) compared with gas-exchange images (6.25 × 6.25 × 6.25 mm3 ), both competitive with current standards within the Xe-MRI field. Moreover, the short 10 s Xe-MRI acquisition time allows for 1 H "anatomic" images used for thoracic cavity masking to be acquired within the same breath-hold for a total scan time of about 14 s. Images were acquired using this single-breath method in 11 volunteers (N = 4 healthy, N = 7 post-acute COVID). For 11 of these participants, a separate breath-hold was used to acquire a "dedicated" ventilation scan and five had an additional "dedicated" gas exchange scan. The images acquired using the single-breath protocol were compared with those from dedicated scans using Bland-Altman analysis, intraclass correlation (ICC), structural similarity, peak signal-to-noise ratio, Dice coefficients, and average distance. Imaging markers from the single-breath protocol showed high correlation with dedicated scans (ventilation defect percent, ICC = 0.77, p = 0.01; membrane/gas, ICC = 0.97, p = 0.001; red blood cell/gas, ICC = 0.99, p < 0.001). Images showed good qualitative and quantitative regional agreement. This single-breath protocol enables the collection of essential Xe-MRI information within one breath-hold, simplifying scanning sessions and reducing costs associated with Xe-MRI.


Assuntos
COVID-19 , Isótopos de Xenônio , Humanos , Pulmão/diagnóstico por imagem , Respiração , Suspensão da Respiração , Imageamento por Ressonância Magnética/métodos , Gases
16.
Magn Reson Med ; 90(2): 473-482, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36989185

RESUMO

PURPOSE: To mitigate signal variations caused by inhomogeneous RF and magnetization decay in hyperpolarized 129 Xe ventilation images using flip-angle maps generated from sequential 2D spiral ventilation images acquired in a breath-hold. Images and correction maps were compared with those obtained using conventional, 2D gradient-recalled echo. THEORY AND METHODS: Analytical expressions to predict signal intensity and uncertainty in flip-angle measurements were derived from the Bloch equations and validated by simulations and phantom experiments. Imaging in 129 Xe phantoms and human subjects (1 healthy, 1 cystic fibrosis) was performed using 2D gradient-recalled echo and spiral. For both sequences, consecutive images were acquired with the same slice position during a breath-hold (Cartesian scan time = 15 s; spiral scan time = 5 s). The ratio of these images was used to calculate flip-angle maps and correct intensity inhomogeneities in ventilation images. RESULTS: Mean measured flip angle showed excellent agreement with the applied flip angle in simulations (R2 = 0.99) for both sequences. Mean measured flip angle agreed well with the globally applied flip angle (∼15% difference) in 129 Xe phantoms and in vivo imaging using both sequences. Corrected images displayed reduced coil-dependent signal nonuniformity relative to uncorrected images. CONCLUSIONS: Flip-angle maps were obtained using sequentially acquired, 2D spiral, 129 Xe ventilation images. Signal intensity variations caused by RF-coil inhomogeneity can be corrected by acquiring sequential single-breath ventilation images in less than 5-s scan time. Thus, this method can be used to remove undesirable heterogeneity while preserving physiological effects on the signal distribution.


Assuntos
Pulmão , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem , Pulmão/fisiologia , Respiração , Imagens de Fantasmas , Suspensão da Respiração , Isótopos de Xenônio
17.
Chest ; 164(3): 700-716, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36965765

RESUMO

BACKGROUND: Microvascular abnormalities and impaired gas transfer have been observed in patients with COVID-19. The progression of pulmonary changes in these patients remains unclear. RESEARCH QUESTION: Do patients hospitalized with COVID-19 without evidence of architectural distortion on structural imaging exhibit longitudinal improvements in lung function measured by using 1H and 129Xe MRI between 6 and 52 weeks following hospitalization? STUDY DESIGN AND METHODS: Patients who were hospitalized with COVID-19 pneumonia underwent a pulmonary 1H and 129Xe MRI protocol at 6, 12, 25, and 51 weeks following hospital admission in a prospective cohort study between November 2020 and February 2022. The imaging protocol was as follows: 1H ultra-short echo time, contrast-enhanced lung perfusion, 129Xe ventilation, 129Xe diffusion-weighted, and 129Xe spectroscopic imaging of gas exchange. RESULTS: Nine patients were recruited (age 57 ± 14 [median ± interquartile range] years; six of nine patients were male). Patients underwent MRI at 6 (n = 9), 12 (n = 9), 25 (n = 6), and 51 (n = 8) weeks following hospital admission. Patients with signs of interstitial lung damage were excluded. At 6 weeks, patients exhibited impaired 129Xe gas transfer (RBC to membrane fraction), but lung microstructure was not increased (apparent diffusion coefficient and mean acinar airway dimensions). Minor ventilation abnormalities present in four patients were largely resolved in the 6- to 25-week period. At 12 weeks, all patients with lung perfusion data (n = 6) showed an increase in both pulmonary blood volume and flow compared with 6 weeks, although this was not statistically significant. At 12 weeks, significant improvements in 129Xe gas transfer were observed compared with 6-week examinations; however, 129Xe gas transfer remained abnormally low at weeks 12, 25, and 51. INTERPRETATION: 129Xe gas transfer was impaired up to 1 year following hospitalization in patients who were hospitalized with COVID-19 pneumonia, without evidence of architectural distortion on structural imaging, whereas lung ventilation was normal at 52 weeks.


Assuntos
COVID-19 , Isótopos de Xenônio , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem
18.
Magn Reson Med ; 89(6): 2217-2226, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36744585

RESUMO

PURPOSE: Imaging of the different resonances of hyperpolarized 129 Xe in the brain and lungs was performed using a 3D sampling density-weighted MRSI technique in healthy volunteers. METHODS: Four volunteers underwent dissolved-phase hyperpolarized 129 Xe imaging in the lung with the MRSI technique, which was designed to improve the point-spread function while preserving SNR (1799 phase-encoding steps, 14-s breath hold, 2.1-cm isotropic resolution). A frequency-tailored RF excitation pulse was implemented to reliably excite both the 129 Xe gas and dissolved phase (tissue/blood signal) with 0.1° and 10° flip angles, respectively. Images of xenon gas in the lung airspaces and xenon dissolved in lung tissue/blood were used to generate quantitative signal ratio maps. The method was also optimized and used for imaging dissolved resonances of 129 Xe in the brain in 2 additional volunteers. RESULTS: High-quality regional spectra of hyperpolarized 129 Xe were achieved in both the lung and the brain. Ratio maps of the different xenon resonances were obtained in the lung with sufficient SNR (> 10) at both 1.5 T and 3 T, making a triple Lorentzian fit possible and enabling the measurement of relaxation times and xenon frequency shifts on a voxel-wise basis. The imaging technique was successfully adapted for brain imaging, resulting in the first demonstration of 3D xenon brain images with a 2-cm isotropic resolution. CONCLUSION: Density-weighted MRSI is an SNR and encoding-efficient way to image 129 Xe resonances in the lung and the brain, providing a valuable tool to quantify regional spectroscopic information.


Assuntos
Imageamento por Ressonância Magnética , Isótopos de Xenônio , Humanos , Isótopos de Xenônio/química , Imageamento por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem , Xenônio , Imageamento Tridimensional/métodos
19.
J Magn Reson ; 348: 107387, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36731353

RESUMO

Magnetic Resonance Imaging (MRI) is dictated by the magnetization of the sample, and is thus a low-sensitivity imaging method. Inhalation of hyperpolarized (HP) noble gases, such as helium-3 and xenon-129, is a non-invasive, radiation-risk free imaging technique permitting high resolution imaging of the lungs and pulmonary functions, such as the lung microstructure, diffusion, perfusion, gas exchange, and dynamic ventilation. Instead of increasing the magnetic field strength, the higher spin polarization achievable from this method results in significantly higher net MR signal independent of tissue/water concentration. Moreover, the significantly longer apparent transverse relaxation time T2* of these HP gases at low magnetic field strengths results in fewer necessary radiofrequency (RF) pulses, permitting larger flip angles; this allows for high-sensitivity imaging of in vivo animal and human lungs at conventionally low (<0.5 T) field strengths and suggests that the low field regime is optimal for pulmonary MRI using hyperpolarized gases. In this review, theory on the common spin-exchange optical-pumping method of hyperpolarization and the field dependence of the MR signal of HP gases are presented, in the context of human lung imaging. The current state-of-the-art is explored, with emphasis on both MRI hardware (low field scanners, RF coils, and polarizers) and image acquisition techniques (pulse sequences) advancements. Common challenges surrounding imaging of HP gases and possible solutions are discussed, and the future of low field hyperpolarized gas MRI is posed as being a clinically-accessible and versatile imaging method, circumventing the siting restrictions of conventional high field scanners and bringing point-of-care pulmonary imaging to global facilities.


Assuntos
Imageamento por Ressonância Magnética , Gases Nobres , Animais , Humanos , Imageamento por Ressonância Magnética/métodos , Isótopos de Xenônio , Pulmão/diagnóstico por imagem , Administração por Inalação , Previsões
20.
J Magn Reson Imaging ; 58(3): 936-948, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36786650

RESUMO

BACKGROUND: Multiple-breath washout (MBW) 129 Xe MRI (MBW Xe-MRI) is a promising technique for following pediatric cystic fibrosis (CF) lung disease progression. However, its repeatability in stable CF needs to be established to use it as an outcome measure for novel therapies. PURPOSE: To assess intravisit and intervisit repeatability of MBW Xe-MRI in healthy and CF children. STUDY TYPE: Prospective, longitudinal cohort study. SUBJECTS: A total of 18 pediatric subjects (7 healthy, 11 CF). FIELD STRENGTH/SEQUENCE: A 3 T/2D coronal hyperpolarized (HP) 129 Xe images using GRE sequence. ASSESSMENT: All subjects completed MBW Xe-MRI, pulmonary function tests (PFTs) (spirometry, nitrogen [N2 ] MBW for lung clearance index [LCI]) and ventilation defect percent (VDP) at baseline (visit 1) and 1-month after. Fractional ventilation (FV), coefficient of variation (CoVFV ) maps were calculated from MBW Xe-MRI data acquired between intervening air washout breaths performed after an initial xenon breath-hold. Skewness of FV and CoVFV map distributions was also assessed. STATISTICAL TESTS: Repeatability: intraclass correlation coefficients (ICC), within-subject coefficient of variation (CV%), repeatability coefficient (CR). Agreement: Bland-Altman. For correlations between MBW Xe-MRI, VDP and PFTs: Spearman's correlation. Significance threshold: P < 0.05. RESULTS: For FV, intravisit median [IQR] ICC was high in both healthy (0.94 [0.48, 0.99]) and CF (0.83 [0.04, 0.97]) subjects. CoVFV also had good intravisit ICC in healthy (0.92 [0.42, 0.99]) and CF (0.79 [0.02, 0.96]) subjects. Similarly, for FV, intervisit ICC was high in health (0.94 [0.68, 0.99]) and CF (0.89 [0.61, 0.97]). CoVFV also had good intervisit ICC in health (0.92 [0.42, 0.99]) and CF (0.78 [0.26, 0.94]). FV had better intervisit repeatability than VDP. CoVFV correlated significantly with LCI (R = 0.56). Skewness of FV distributions significantly distinguished between cohorts at baseline. DATA CONCLUSION: MBW Xe-MRI had high intravisit and intervisit repeatability in healthy and stable CF subjects. CoVFV correlated with LCI, suggesting the importance of ventilation heterogeneity to early CF. EVIDENCE LEVEL: 1. TECHNICAL EFFICACY: Stage 2.


Assuntos
Fibrose Cística , Humanos , Criança , Fibrose Cística/diagnóstico por imagem , Xenônio , Estudos Prospectivos , Estudos Longitudinais , Testes de Função Respiratória/métodos , Pulmão/diagnóstico por imagem , Isótopos de Xenônio , Imageamento por Ressonância Magnética/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...